PH5900 TML Series (10-12kW)
High Frequency On Grid Solar Inverter 17~25KW | Three-phase | MPPT 200V-1000V
PH5900TM series PV inverters take full account of the needs of end customers, It is used to convert the DC generated by photovoltaic panels into AC and send it to the grid in a three-phase manner.with excellent performance at the same time, use LED as inverter status display, effectively improve product life. Using DSP digital control,could afford wide grid voltage range, have a full range of protection features; to maximize the benefits at the same time, greatly enhance the reliability of the product.
- Overview
- Recommended Products
Product Overview
■ Wide MPPT voltage range from 200V-1000V
■ IP66 protection degree
■ Integrated DC switch
■ DSP controller
■ The maximum efficiency is 98.6%
■ Multi MPPT controller
■ WIFI monitoring standard
■ Easy installation

Specification
| MODEL | PH59-17000 TM | PH59-18000 TM | PH59-19000 TM | PH59-20000 TM | PH59-21000 TM | PH59-22000 TM | PH59-23000 TM | PH59-24000 TM | PH59-25000 TM |
| Rated AC output power | 17000W | 18000W | 19000W | 20000W | 21000W | 22000W | 23000W | 24000W | 25000W |
| OUTPUT (AC) | |||||||||
| Max.AC apparent power | 18700VA | 19800VA | 20900VA | 22000VA | 23100VA | 24200VA | 25300VA | 26400VA | 27500VA |
| Max.output current | 27.1A | 28.6 | 30.2 | 31.8A | 33.5A | 35A | 36.6A | 38A | 39A |
| Nominal AC Voltage | 230V/400V | ||||||||
| AC Voltage range | 320-478V | ||||||||
| AC grid frequency range | 50/60±5Hz | ||||||||
| Power factor at Rated power | 1 | ||||||||
| Adjustable displacement power factor | 0.8leading. 0.8lagging | ||||||||
| Total harmonic distortion (THDi) | < 3% | ||||||||
| AC grid connection type | 3W+N+PE | ||||||||
| INPUT DATA | |||||||||
| Max.recommended PV power | 20400W | 21600W | 22800W | 24000W | 25200W | 26400W | 27600W | 28800W | 30000W |
| Max.DC voltage | 1100V | ||||||||
| Start voltage | 250V | ||||||||
| Nominal voltage | 600V | ||||||||
| MPPT voltage range | 200V-1000V | ||||||||
| Max.input current | 26A/26A | 26A/26A | 26A/26A | 26A/26A | 26A/39A | 26A/39A | 26A/39A | 26A/39A | 26A/39A |
| Number of independent MPP trackers/ strings per MPP tracker | 2/2 | 2/2 | 2/2 | 2/2 | 2/2+3 | 2/2+3 | 2/2+3 | 2/2+3 | 2/2+3 |
| DC connection | H4 / MC4 | ||||||||
| EFFICIENCY | |||||||||
| Max.efficiency | 98.30% | 98.60% | |||||||
| Euro weighted efficiency | 98% | 98% | 98% | 98% | 98.30% | 98.30% | 98.30% | 98.30% | 98.30% |
| MPPT efficiency | 99.50% | ||||||||
| Protection devices | Island protection, DC reverse polarity protection , Output over current protection, Output overvoltage protection-varistor, Integrated DC switch, Ground fault monitoring, | ||||||||
| Integrated all-pole sensitive leakage current monitoring unit, DC Surge protection, AC Surge protection | |||||||||
| GENERAL DATA FEATURES | |||||||||
| Machine Dimension (W*H*D)(mm) | 540*426*234 | ||||||||
| Package Dimension (W*H*D)(mm) | 650*338*542 | ||||||||
| N.W(kg) | 28.6 | ||||||||
| G.W(kg) | 32.5 | ||||||||
| Operation temperature range | -25°C- +60°C with derating above 45°C | ||||||||
| Noise emission(typical) | ≤40dB(A) | ||||||||
| Altitude | 3000m | ||||||||
| Self-consumption (night) | < 1W | ||||||||
| Topology | Transformerless | ||||||||
| Cooling concept | Fan cooling | ||||||||
| Environmental protection Rating | IP66 | ||||||||
| Relative humidity | 0~100% | ||||||||
| FEATURES | |||||||||
| AC connection | Connector | ||||||||
| Display | LED | ||||||||
| Communication interfaces | WIFI/RS485/GPRS(opt) | ||||||||
| Warranty | Standard 5 years / 10 years (opt.) | ||||||||
| CERTIFICATION & STANDARDS | |||||||||
| CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011) IEC60529; EN50549-1:2019; UNE217001-2020; UNE217002-2020, NTS-631:2021 (Type A); G99 | |||||||||